- Joe Kerwin (CAPCOM)
-
Okay; probably okay, Fred. Read it nice and slow so we'll be sure to get it. Over.
- Fred Haise (LMP)
-
Okay. Jack pushed in the 250 BAT A, BAT B entry breakers. He read battery bus volts as 32.3 on A, 37.0 on B. Then he pushed in the 275 breakers tying the BATs to the main buses. In this configuration, MAIN A is at 32.0 volts, zero amps; MAIN B is at 37.0 volts, zero amps. So it looks like the buses are okay.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. Copy those numbers and thank you very much. I assume you got them off all right.
- Fred Haise (LMP)
-
Okay. I'd just like to … how's—how's our lith-o cartridge setup … appear to be working down there.
- Joe Kerwin (CAPCOM)
-
We are reading 0.2 on our CO2 sets here, and we're all delighted. It seems to be working fine.
- Joe Kerwin (CAPCOM)
-
And Fred, Houston. In a little while here, I'm going to have a procedure that I want to read up to you and have you copy down for future use. It's a procedure for powering the command module main bus off the LM, and it's something that we feel that's going to come in real handy later on for such things as popping off the command module entry batteries, and also possibly for doing some preheating and preliminary powering up of the command module before we get rid of the LM. We'll have that for you in probably 10 or 15 minutes. Over.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. Our procedure-generating mill has generated another very short one for you here. It's a procedure for getting an onboard read-out —
- Joe Kerwin (CAPCOM)
-
Okay, Fred. This is a procedure for getting a read-out of the descent propellant tank temps. It's no big problem, but our LM people say that the bottom of the descent stage is probably cooling off, and we just want to verify that the descent water tank will be okay. Right now, it looks as though it won't freeze until several hours after it's empty, but we want to have you read these temperatures out to us so we can see how good our predictions are. The procedure is, on panel 16, close the PROPELLANT DISPLAY/ENGINE OVERRIDE LOGIC circuit breaker. Over.
- Fred Haise (LMP)
-
Okay. The PROPELLANT DISPLAY OVERRIDE circuit breakers are closed. … the propellant.
- Joe Kerwin (CAPCOM)
-
Right, Fred. The next step is simply to turn the PROPELLANT TEMP PRESS MONITOR switch to DESCENT 1, read the fuel and OX temps, turn it to DESCENT 2, read the fuel and OX temps; tell us what they are.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. We're in noisy COMM here; I got DESCENT 1 fuel 66.5; stand by a second.
- Fred Haise (LMP)
-
On DESCENT TANK 2, fuel is reading 60—Okay. DESCENT 2 fuel is reading 68 degrees; oxidizer, 65 degrees.
- Joe Kerwin (CAPCOM)
-
Okay. Copy that, Fred. Thank you. We'd like you to pull the circuit breaker, and we'll probably come to you again in 5 or 6 hours for another check.
- Joe Kerwin (CAPCOM)
-
Okay. We're chasing a small glitch that we saw a while ago in the O2 flow rate which is now normal again, but what we'd like you to do is, first of all, to tell us whether, during that canister procedure, you moved O2 DEMAND REG A to any position other than CABIN, and then we'd like you to move it to OFF momentarily and back to CABIN for us.
- Fred Haise (LMP)
-
Okay. To answer your question, Joe, it's no. I checked the CABIN all the time. Qualitatively, when we switched to this configuration, it didn't seem like the frequency or the suit fan noise … decreased … logged down a little bit, but I'll follow your procedure. You want me to take REG A, go to close and back to CABIN; is that correct?
- Joe Kerwin (CAPCOM)
-
I'm not sure I copied that, Fred. If you asked me whether I had that powerup procedure, I don't have it for you, yet. Over.
- Joe Kerwin (CAPCOM)
-
Gol darn it. Just as you started talking, it got noisy again, Fred; try it again.
- Joe Kerwin (CAPCOM)
-
On how far out what?
Expand selection down Contract selection up - Joe Kerwin (CAPCOM)
-
Oh. Our little plot shows you just touching the 180-thousand-mile line. So you're about 40 K out from the Moon.
- Fred Haise (LMP)
-
Okay. Okay. And the other thing is, we've noticed some fresh new particles floating around outside, so possibly the service module is starting to vent a little bit again.
- Joe Kerwin (CAPCOM)
-
Okay. Copy that, Fred. On the O2 flow thing, we clearly saw the DEMAND REGULATOR go to OFF and back to CABIN. TELMU thinks that it's no big thing that you've seen a little change in flow due to the different resistance we've got in the circuit.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. Recommend you go to OFF on the BIOMED switch. We never did get any BIOMED and it might clear up the COMM a little bit.
- Jack Swigert (CMP)
-
That midcourse should be interesting. You know, the mode we're going to do it in.
- Jack Swigert (CMP)
-
We can't help them too much. Actually it isn't bad … but … … goddamned unfortunate. In part, I get a feeling … now when I get … Just before … goes to zero in 1 second I'm going to pull them out …
- Fred Haise (LMP)
-
Well, hell, Jack. All you—you don't use a very good one … Just if you'll go … at your attitude reference for … and the g-meter backup. Because, really, you can almost … The command module and your odds are 60 to 40 that you're going to hit Earth blunt-end first, without any reference.
- Jack Swigert (CMP)
-
… I didn't realize that. That proves you've got a little bit above 50-percent odds that you're going to enter blunt end, and -
- Fred Haise (LMP)
-
We made an entry like that in Apollo 8 in a … with Houston, ol' Buzz went and turned on the command module heaters and left them on. The activators, they went, “Shooo!” both tanks; we had no gas. Just had a real slow rate … We actually went out in the console and started debriefing, but left it running and watched it; and the son of a bitch did a hop-skipout, a hopout, underneath …, but not much, and then we did a long hop … but—The second reentry, also, it did one … both times. It lucked out twice and made a real peculiar … They went to zero g …
Spoken on April 15, 1970, 6:03 p.m. UTC (54 years, 7 months ago). Link to this transcript range is: Tweet