Joe Kerwin (CAPCOM)

Okay. And circuit breakers on panel 5 we want all open. Over.

Joe Kerwin (CAPCOM)

Okay. On panel 6, skip the first one. We want POWER to OFF, and skip down then to SUIT POWER to OFF. Over.

Joe Kerwin (CAPCOM)

Okay. On panel 7 we want EDS POWER, OFF. TVC SERVO POWER 1 and 2, OFF; FDAI/GPI POWER, OFF; and LOGIC 2 slash 3 POWER, OFF. Over.

Jack Swigert (CMP)

Okay. I'll read back. SUIT COMPRESSOR 1 and 2, OFF; FUEL CELL PUMPS 1, 2, and 3, OFF; G/N POWER, OFF; MAIN BUS TIES, OFF; INTERIOR INTEGRAL LIGHTING, OFF; INTERIOR FLOODLIGHTING, OFF; then coming down, all circuit breakers on panel open; panel 6, the POWER should be OFF; SUIT POWER should be OFF; panel 7, all 5 of those switches should be OFF.

Expand selection down Contract selection up

Spoken on April 15, 1970, 3:26 p.m. UTC (54 years, 6 months ago). Link to this transcript range is: Tweet

Joe Kerwin (CAPCOM)

Okay, Jack. That's correct. Go to page 1-7. SCS ELECTRONICS POWER, OFF; SCS SIGNAL CONDITIONER/ DRIVER BIAS 1 and 2, OFF; and BMAG POWER, both, OFF; and DIRECT O2 valve to close. Over.

Jack Swigert (CMP)

Okay. SCS ELECTRONICS POWER, OFF; both SIGNAL CONDITIONER/DRIVER BIAS POWER, OFF; BMAG POWER, two of them OFF; DIRECT O2 to close.

Joe Kerwin (CAPCOM)

Okay. Now on panel 8, I'm going to have to read you a number of circuit breakers that we want open, and so start with CB panel 8 all closed except leave the two that we have there CM/RCS HEATERS, open, and FLOAT BAG open, and add the following. I'll read them up one at a time, and you can Roger. SCS LOGIC BUS, four, to open. Over.

Jack Swigert (CMP)

SCS LOGIC BUS, four, open.

Joe Kerwin (CAPCOM)

Right. SPS PITCH and YAW, four, to open.

Jack Swigert (CMP)

SPS PITCH and YAW, four, to open.

Joe Kerwin (CAPCOM)

Roger. SPS GAGING, four, to open.

Jack Swigert (CMP)

SPS GAGING, four, open.

Joe Kerwin (CAPCOM)

Okay. And SEQ ARM, two, open.

Jack Swigert (CMP)

Okay. Are you with me? SEQ ARM, two of them open.

Joe Kerwin (CAPCOM)

Roger. The next is EDS, three, to open.

Joe Kerwin (CAPCOM)

Roger. The next are ELS BAT A, BAT B, two, open.

Jack Swigert (CMP)

ELRS BAT A and BAT B, two of them, open.

Joe Kerwin (CAPCOM)

Roger. POSTLANDING VENT FLIGHT slash POSTLANDING to open.

Jack Swigert (CMP)

Okay. POSTLANDING and POSTLANDING VENT, open.

Joe Kerwin (CAPCOM)

Okay. That was the—Yes, the POSTLANDING VENT, that's FLT/PL, to open. The next are SCS DIRECT ULLAGE, two, to open.

Jack Swigert (CMP)

SCS DIRECT ULLAGE, two, open.

Joe Kerwin (CAPCOM)

That's correct, and the next ones are SM RCS HEATER A MAIN B, and HEATER C MAIN B, open.

Jack Swigert (CMP)

Okay, SERVICE MODULE RCS HEATER MAIN B, open, and HEATER C MAIN B, open.

Joe Kerwin (CAPCOM)

That's correct, and SM RCS HEATER B MAIN A, open, and HEATER D MAIN A, open. Over.

Joe Kerwin (CAPCOM)

Okay, Jack. That's the last of the additions to this page. Go back to the regular checklist, and go to the AUTO RCS SELECT switches. We want all 16 of them open. Over. That is OFF.

Jack Swigert (CMP)

Okay. Okay. They're sitting at OFF right now. All 16 AUTO RCS switches OFF.

Joe Kerwin (CAPCOM)

Okay. Then we go down to interior NUMERIC LIGHTING-LIGHTING, OFF; INTERIOR INTEGRAL LIGHTING, OFF; and INTERIOR FLOOD LIGHTING, OFF. Over.

Joe Kerwin (CAPCOM)

Okay. Skip 3. We want SECs LOGIC, two OFF, down, and SECs PYRO ARM, two OFF, down. Over.

Joe Kerwin (CAPCOM)

Okay, and on panel 9: POWER to OFF. Over.

Joe Kerwin (CAPCOM)

Okay, Jack. I don't think you need to read back all the circuit breakers because we copied them as you went. If you just want to read back—the panel 8, panel 9 changes.

Jack Swigert (CMP)

All right, let's do it. SCS ELECTRONICS POWER, OFF. … panel 8. All 16 RCS switches, OFF. INTERIOR NUMERICS LIGHTING, OFF; INTERIOR INTEGRAL, OFF; INTERIOR FLOOD LIGHTING, OFF. SPS LOGIC, two, down and OFF. PYRO ARM, down and OFF. Then panel 9 is POWER to OFF.

Joe Kerwin (CAPCOM)

Okay; that's correct, Jack. Let's go to page 1-8. In the second line, SUIT POWER's OFF. Over.

Joe Kerwin (CAPCOM)

Okay, Jack. COMM sounds a little —

Jack Swigert (CMP)

— … too many changes here.

Joe Kerwin (CAPCOM)

— COMM sounds better now, Jack —

Jack Swigert (CMP)

Okay, we're back. We —

Joe Kerwin (CAPCOM)

Good. SUIT POWER was OFF, and then go to panel 10, POWER, OFF, and SUIT POWER, OFF. Over.

Joe Kerwin (CAPCOM)

Okay. And that's the only changes on pages 1-8. Over.

Jack Swigert (CMP)

Okay. SUIT POWER, OFF; panel 10, POWER and SUIT POWER, OFF.

Joe Kerwin (CAPCOM)

That's correct. Go to page 1-9 and on panel 100, skip the first four. We want IMU POWER, OFF. Over.