- Joe Kerwin (CAPCOM)
-
Jack, Houston. The COMM kind of gets better and worse and the last one I copied was RCS TRANSFER to center. Start from there.
- Jack Swigert (CMP)
-
Okay. And that's exactly where I was. COMMAND MODULE RCS PROPELLANT 2, center, on, up; PROPELLANT talkbacks, two, gray; SERVICE MODULE RCS SECONDARY FUEL PRESSURE, four, center, and CLOSED; EDS AUTO, OFF; COMMAND MODULE/LM FINAL SEP, two, off; COMMAND MODULE/SERVICE MODULE SEP, two, down; S-IVB/LM SEP, off, down, guarded; PROPELLANT DUMP to RCS COMMAND; 2 ENGINE OUT and LV RATES, OFF.
- Joe Kerwin (CAPCOM)
-
Okay. That's correct. Let's go to page 3, and the first one on page 3, TOWER JETT, two to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three, four, five, six, seven are the same, and then we get CAUTION/WARNING NORMAL to ACK, CAUTION/WARNING CSM to CM, and CAUTION/WARNING POWER to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three, four are the same, and then we get to the H2 HEATERS, two, OFF; and the O2 HEATERS, two, OFF. Got that?
- Jack Swigert (CMP)
-
Okay. POWER JETT, two, OFF. And then I'll just go on down: CAUTION and WARNING NORMAL to ACKNOWLEDGE; CAUTION and WARNING CSM—CAUTION and WARNING CSM to CM; CAUTION and WARNING POWER, OFF; H2 and O2 HEATERS, OFF.
- Joe Kerwin (CAPCOM)
-
That's correct, Jack. Those are the only changes on 1-3. Now, let's go to 1-4. No changes on the remaining three panel 2 switches. On panel 3, the first one, two, three, four are unchanged and then we want FUEL CELL HEATERS, three, to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three, four, five, six, seven, eight are the same, and then we want FUEL CELL 2 MAIN BUS A to OFF; and, skipping one, we want FUEL CELL 2 MAIN BUS A to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, we want MAIN BUS A RESET to OFF; skip one, and we want FUEL CELL 1 MAIN BUS B talkback to gray. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip one, and we want FUEL CELL 2 MAIN BUS B talkback, gray; and, the next one, we want FUEL CELL 3 MAIN BUS B to OFF. Over.
- Joe Kerwin (CAPCOM)
-
All right. Then the next one, two, three, four, five, six are the same, and then we want S-BAND TRANSPONDER to center, OFF; skip one, and we want S-BAND POWER AMPLIFIER, HIGH to center, OFF; and the POWER AMPLIFIER talkback to barber pole. Over.
- Jack Swigert (CMP)
-
Okay. Read back the changes on this page—Stand by. I … another OMNI.
Expand selection up Contract selection down Close - Jack Swigert (CMP)
-
Okay. I've just got to switch OMNIs. Okay. Reading the changes, Joe, on pages 1-4, FUEL CELL HEATERs three, OFF, coming down to FUEL CELL 1 MAIN BUS A center—MAIN BUS A to OFF; MAIN BUS—FUEL CELL 2 to MAIN BUS A, OFF; FUEL CELL 3 to MAIN BUS A, talkback, gray; MAIN BUS A RESET to OFF; FUEL CELL, 1 to MAIN BUS B talkback, gray; FUEL CELL 2 to MAIN BUS B talkback, gray; FUEL CELL 3 to MAIN BUS B to OFF; MAIN BUS B RESET, OFF; S-BAND TRANSPONDER to OFF; S-BAND POWER AMPLIFIER, HIGH to OFF; POWER AMPLIFIER talkback barber pole.
- Joe Kerwin (CAPCOM)
-
Okay, Jack. That's completely correct on 1-4. Let's go to 1-5, and on that page the first one, two, three, four, five, six are the same, and we want UP TELEMETRY COMMAND to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three are the same, and we want VHF AM B to center. Over.
- Joe Kerwin (CAPCOM)
-
The next one, two, three, four are the same, and we want S-BAND SQUELCH to OFF, and FUEL CELL REACTANT VALVE, to NORMAL. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three are the same, and then we want TAPE RECORDER FORWARD to center; TAPE MOTION talkback, barber pole; SCE POWER to center; and PMP POWER to center. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip the next one, and we want AC INVERTER 1 to OFF, and AC INVERTER 2 to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip the next one, and we want INVERTER 1 AC 1 to OFF, and skip two and we want AC 1 RESET to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip 1, and we want INVERTER 2 AC 2 to OFF; and skip 1, and we want AC 2, BUS to RESET—AC 2 BUS RESET to OFF.
- Joe Kerwin (CAPCOM)
-
That was AC 2 BUS RESET, wasn't it? Okay. Skip the next one, and on panel 4, we want SPS GAGING to OFF; TELCOM GROUP 1 to OFF; TELCOM GROUP 2 to OFF; and GLYCOL PUMPS to OFF. Over.
- Jack Swigert (CMP)
-
Okay. Reading back UP TELEMETRY COMMAND to OFF; VHF AM B, center; S-BAND SQUELCH to OFF; FUEL CELL REACS VALVES to NORMAL; TAPE RECORDER FORWARD, center; TAPE MOTION, barberpole; SCE POWER, center; PMP POWER, center; AC INVERTER 1, OFF; AC INVERTER 2, OFF; INVERTER 1 to AC 1, OFF; AC 1 RESET, OFF; INVERTER 2 to AC 2, OFF; AC 2 BUS RESET, OFF; and coming to panel 4, SPS GAGING; TELCOM, GROUP 1; TELCOM, GROUP 2; and GLYCOL PUMPS all OFF.
- Joe Kerwin (CAPCOM)
-
Okay. That's correct on 1-5, Jack. Let's go to the 1-6. And the first line we want SUIT COMPRESSORS, both, to OFF. Over.
- Joe Kerwin (CAPCOM)
-
You're loud and clear now, and let's go to panel 5. We want FUEL CELL PUMP AC 1, OFF; AC 2, OFF; and that's the FUEL CELL 1 PUMP, AC 1, OFF; FUEL CELL 2 PUMPS, AC 2, OFF; FUEL CELL B PUMPS, AC 2, OFF; G/N POWER, OFF, and both the MAIN BUS TIEs OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip two, and then we want INTERIOR INTEGRAL LIGHTING, OFF; and INTERIOR FLOODLIGHT, OFF. Scratch out “Full dim or full bright.” Over.
- Joe Kerwin (CAPCOM)
-
Okay. On panel 6, skip the first one. We want POWER to OFF, and skip down then to SUIT POWER to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. On panel 7 we want EDS POWER, OFF. TVC SERVO POWER 1 and 2, OFF; FDAI/GPI POWER, OFF; and LOGIC 2 slash 3 POWER, OFF. Over.
- Jack Swigert (CMP)
-
Okay. I'll read back. SUIT COMPRESSOR 1 and 2, OFF; FUEL CELL PUMPS 1, 2, and 3, OFF; G/N POWER, OFF; MAIN BUS TIES, OFF; INTERIOR INTEGRAL LIGHTING, OFF; INTERIOR FLOODLIGHTING, OFF; then coming down, all circuit breakers on panel open; panel 6, the POWER should be OFF; SUIT POWER should be OFF; panel 7, all 5 of those switches should be OFF.
- Joe Kerwin (CAPCOM)
-
Okay, Jack. That's correct. Go to page 1-7. SCS ELECTRONICS POWER, OFF; SCS SIGNAL CONDITIONER/ DRIVER BIAS 1 and 2, OFF; and BMAG POWER, both, OFF; and DIRECT O2 valve to close. Over.
- Jack Swigert (CMP)
-
Okay. SCS ELECTRONICS POWER, OFF; both SIGNAL CONDITIONER/DRIVER BIAS POWER, OFF; BMAG POWER, two of them OFF; DIRECT O2 to close.
- Joe Kerwin (CAPCOM)
-
Okay. Now on panel 8, I'm going to have to read you a number of circuit breakers that we want open, and so start with CB panel 8 all closed except leave the two that we have there CM/RCS HEATERS, open, and FLOAT BAG open, and add the following. I'll read them up one at a time, and you can Roger. SCS LOGIC BUS, four, to open. Over.
- Joe Kerwin (CAPCOM)
-
Okay. That was the—Yes, the POSTLANDING VENT, that's FLT/PL, to open. The next are SCS DIRECT ULLAGE, two, to open.
- Joe Kerwin (CAPCOM)
-
That's correct, and the next ones are SM RCS HEATER A MAIN B, and HEATER C MAIN B, open.
- Joe Kerwin (CAPCOM)
-
That's correct, and SM RCS HEATER B MAIN A, open, and HEATER D MAIN A, open. Over.
- Joe Kerwin (CAPCOM)
-
Okay, Jack. That's the last of the additions to this page. Go back to the regular checklist, and go to the AUTO RCS SELECT switches. We want all 16 of them open. Over. That is OFF.
- Joe Kerwin (CAPCOM)
-
Okay. Then we go down to interior NUMERIC LIGHTING-LIGHTING, OFF; INTERIOR INTEGRAL LIGHTING, OFF; and INTERIOR FLOOD LIGHTING, OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip 3. We want SECs LOGIC, two OFF, down, and SECs PYRO ARM, two OFF, down. Over.
- Joe Kerwin (CAPCOM)
-
Okay, Jack. I don't think you need to read back all the circuit breakers because we copied them as you went. If you just want to read back—the panel 8, panel 9 changes.
- Jack Swigert (CMP)
-
All right, let's do it. SCS ELECTRONICS POWER, OFF. … panel 8. All 16 RCS switches, OFF. INTERIOR NUMERICS LIGHTING, OFF; INTERIOR INTEGRAL, OFF; INTERIOR FLOOD LIGHTING, OFF. SPS LOGIC, two, down and OFF. PYRO ARM, down and OFF. Then panel 9 is POWER to OFF.
- Joe Kerwin (CAPCOM)
-
Okay; that's correct, Jack. Let's go to page 1-8. In the second line, SUIT POWER's OFF. Over.
- Joe Kerwin (CAPCOM)
-
Good. SUIT POWER was OFF, and then go to panel 10, POWER, OFF, and SUIT POWER, OFF. Over.
- Joe Kerwin (CAPCOM)
-
That's correct. Go to page 1-9 and on panel 100, skip the first four. We want IMU POWER, OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip the next one, and we want NUMERICS LIGHTING, OFF; FLOOD LIGHTS, OFF; and INTEGRAL LIGHTS, OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. On panel 101, skip the first three. We want URINE DUMP to OFF, and WASTE WATER DUMP to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Panel 162, no change. Panel 163, no change. Now add, in panel 201, FOOD WARMER to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. On panel 225. It will read the same except I have three additional circuit breakers that we want open, and I'll read them up one at a time. The first one is S-BAND FM TRANSMITTER DSE, GROUP 1, open. Over.
- Joe Kerwin (CAPCOM)
-
Roger that. The next one is FLIGHT BUS, MAIN A and MAIN B, and that's two breakers, both open.
- Jack Swigert (CMP)
-
Okay. Let me read it back here. … order … POWER, OFF. NUMERICS LIGHTING, FLOOD LIGHTING, and INTEGRAL LIGHTING, three of them, OFF. Panel 101, URINE DUMP HEATERS, URINE DUMP to OFF, WASTE H2O to OFF. Panel 122, CONDITION LAMPS, OFF. Panel 201, FOOD WARMER, OFF. Panel 225, add additions that I read: S-BAND TRANSMITTER DSE, GROUP 1; FLIGHT BUS, MAIN A and MAIN B, CET, two to open.
- Joe Kerwin (CAPCOM)
-
Okay. On panel 226, we want all open except; so change word “Closed” to “Open” and then scratch out the next three lines because we want them open, too. Over.
- Joe Kerwin (CAPCOM)
-
Right. I'll give you the opens now. We want LIGHTING: FLOOD, MAIN A, MAIN B, and FLIGHT/POSTLANDING, closed.
- Jack Swigert (CMP)
-
Okay. LIGHTING: FLOOD, MAIN A; LIGHTING: FLOOD, MAIN B, closed; and FLIGHT/POSTLANDING, closed.
- Joe Kerwin (CAPCOM)
-
Roger, Jack. EECOM tells me that's all one circuit breaker, and the next one is LIGHTING: NUMERICS/INTEGRAL, LEB AC2, LMDC-AC1, and RMDC-AC1 to closed, and that's one circuit breaker also.
- Jack Swigert (CMP)
-
Okay. I don't know whether I can read that all back. Okay, LIGHTING: NUMERIC/INTEGRAL and I didn't get the rest of it, Joe -
- Joe Kerwin (CAPCOM)
-
Okay. On the 226 circuit breakers that I read up, they are—there are six circuit breakers involved and they're all—they're the first six from the left on the bottom row of the panel. They're under LIGHTING. We want the three FLOOD circuit breakers out and the three NUMERIC/INTEGRAL circuit breakers—I don't mean out, I mean closed. Those six closed and the rest open. Over.
- Jack Swigert (CMP)
-
Okay. There are three FLOOD circuit breakers and three NUMERIC circuit breakers and you want all six of those closed.
- Joe Kerwin (CAPCOM)
-
That's affirmative, Jack, and all the rest open. Okay. Panel 227, no change, and panel 229, one addition to the circuit breakers we want open, and those are the TIMERS, MAIN A and MAIN B, two, to open. Over.
- Joe Kerwin (CAPCOM)
-
Wait 1 minute. Yes, EECOM caught me; I said that wrong. We want you to change the word “Closed” to “Open,” and then scratch out the ones that are there.
- Jack Swigert (CMP)
-
Okay. All open …
Expand selection down Contract selection up - Jack Swigert (CMP)
-
Okay. I had to switch OMNIs here. And the two you want all open on panel 250 except SEQUENCE A and SEQUENCE B.
- Joe Kerwin (CAPCOM)
-
That's correct. Panel 251, no change; panel 252, WASTE STOWAGE VENT valve, closed. Over.
Spoken on April 15, 1970, 3:20 p.m. UTC (54 years, 6 months ago). Link to this transcript range is: Tweet