- Joe Kerwin (CAPCOM)
-
Jack, Houston. The COMM kind of gets better and worse and the last one I copied was RCS TRANSFER to center. Start from there.
- Jack Swigert (CMP)
-
Okay. And that's exactly where I was. COMMAND MODULE RCS PROPELLANT 2, center, on, up; PROPELLANT talkbacks, two, gray; SERVICE MODULE RCS SECONDARY FUEL PRESSURE, four, center, and CLOSED; EDS AUTO, OFF; COMMAND MODULE/LM FINAL SEP, two, off; COMMAND MODULE/SERVICE MODULE SEP, two, down; S-IVB/LM SEP, off, down, guarded; PROPELLANT DUMP to RCS COMMAND; 2 ENGINE OUT and LV RATES, OFF.
- Joe Kerwin (CAPCOM)
-
Okay. That's correct. Let's go to page 3, and the first one on page 3, TOWER JETT, two to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three, four, five, six, seven are the same, and then we get CAUTION/WARNING NORMAL to ACK, CAUTION/WARNING CSM to CM, and CAUTION/WARNING POWER to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three, four are the same, and then we get to the H2 HEATERS, two, OFF; and the O2 HEATERS, two, OFF. Got that?
- Jack Swigert (CMP)
-
Okay. POWER JETT, two, OFF. And then I'll just go on down: CAUTION and WARNING NORMAL to ACKNOWLEDGE; CAUTION and WARNING CSM—CAUTION and WARNING CSM to CM; CAUTION and WARNING POWER, OFF; H2 and O2 HEATERS, OFF.
- Joe Kerwin (CAPCOM)
-
That's correct, Jack. Those are the only changes on 1-3. Now, let's go to 1-4. No changes on the remaining three panel 2 switches. On panel 3, the first one, two, three, four are unchanged and then we want FUEL CELL HEATERS, three, to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three, four, five, six, seven, eight are the same, and then we want FUEL CELL 2 MAIN BUS A to OFF; and, skipping one, we want FUEL CELL 2 MAIN BUS A to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip two, and then we want FUEL CELL 3 MAIN BUS A talkback to gray. Over.
Expand selection up Contract selection down Close - Joe Kerwin (CAPCOM)
-
Okay. The next one, we want MAIN BUS A RESET to OFF; skip one, and we want FUEL CELL 1 MAIN BUS B talkback to gray. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip one, and we want FUEL CELL 2 MAIN BUS B talkback, gray; and, the next one, we want FUEL CELL 3 MAIN BUS B to OFF. Over.
Expand selection down Contract selection up - Joe Kerwin (CAPCOM)
-
All right. Then the next one, two, three, four, five, six are the same, and then we want S-BAND TRANSPONDER to center, OFF; skip one, and we want S-BAND POWER AMPLIFIER, HIGH to center, OFF; and the POWER AMPLIFIER talkback to barber pole. Over.
- Jack Swigert (CMP)
-
Okay. I've just got to switch OMNIs. Okay. Reading the changes, Joe, on pages 1-4, FUEL CELL HEATERs three, OFF, coming down to FUEL CELL 1 MAIN BUS A center—MAIN BUS A to OFF; MAIN BUS—FUEL CELL 2 to MAIN BUS A, OFF; FUEL CELL 3 to MAIN BUS A, talkback, gray; MAIN BUS A RESET to OFF; FUEL CELL, 1 to MAIN BUS B talkback, gray; FUEL CELL 2 to MAIN BUS B talkback, gray; FUEL CELL 3 to MAIN BUS B to OFF; MAIN BUS B RESET, OFF; S-BAND TRANSPONDER to OFF; S-BAND POWER AMPLIFIER, HIGH to OFF; POWER AMPLIFIER talkback barber pole.
- Joe Kerwin (CAPCOM)
-
Okay, Jack. That's completely correct on 1-4. Let's go to 1-5, and on that page the first one, two, three, four, five, six are the same, and we want UP TELEMETRY COMMAND to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three are the same, and we want VHF AM B to center. Over.
- Joe Kerwin (CAPCOM)
-
The next one, two, three, four are the same, and we want S-BAND SQUELCH to OFF, and FUEL CELL REACTANT VALVE, to NORMAL. Over.
- Joe Kerwin (CAPCOM)
-
Okay. The next one, two, three are the same, and then we want TAPE RECORDER FORWARD to center; TAPE MOTION talkback, barber pole; SCE POWER to center; and PMP POWER to center. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip the next one, and we want AC INVERTER 1 to OFF, and AC INVERTER 2 to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip the next one, and we want INVERTER 1 AC 1 to OFF, and skip two and we want AC 1 RESET to OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip 1, and we want INVERTER 2 AC 2 to OFF; and skip 1, and we want AC 2, BUS to RESET—AC 2 BUS RESET to OFF.
- Joe Kerwin (CAPCOM)
-
That was AC 2 BUS RESET, wasn't it? Okay. Skip the next one, and on panel 4, we want SPS GAGING to OFF; TELCOM GROUP 1 to OFF; TELCOM GROUP 2 to OFF; and GLYCOL PUMPS to OFF. Over.
- Jack Swigert (CMP)
-
Okay. Reading back UP TELEMETRY COMMAND to OFF; VHF AM B, center; S-BAND SQUELCH to OFF; FUEL CELL REACS VALVES to NORMAL; TAPE RECORDER FORWARD, center; TAPE MOTION, barberpole; SCE POWER, center; PMP POWER, center; AC INVERTER 1, OFF; AC INVERTER 2, OFF; INVERTER 1 to AC 1, OFF; AC 1 RESET, OFF; INVERTER 2 to AC 2, OFF; AC 2 BUS RESET, OFF; and coming to panel 4, SPS GAGING; TELCOM, GROUP 1; TELCOM, GROUP 2; and GLYCOL PUMPS all OFF.
- Joe Kerwin (CAPCOM)
-
Okay. That's correct on 1-5, Jack. Let's go to the 1-6. And the first line we want SUIT COMPRESSORS, both, to OFF. Over.
- Joe Kerwin (CAPCOM)
-
You're loud and clear now, and let's go to panel 5. We want FUEL CELL PUMP AC 1, OFF; AC 2, OFF; and that's the FUEL CELL 1 PUMP, AC 1, OFF; FUEL CELL 2 PUMPS, AC 2, OFF; FUEL CELL B PUMPS, AC 2, OFF; G/N POWER, OFF, and both the MAIN BUS TIEs OFF. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Skip two, and then we want INTERIOR INTEGRAL LIGHTING, OFF; and INTERIOR FLOODLIGHT, OFF. Scratch out “Full dim or full bright.” Over.
Spoken on April 15, 1970, 3:18 p.m. UTC (54 years, 8 months ago). Link to this transcript range is: Tweet