- Jack Swigert (CMP)
-
You wouldn't believe it, but I'm now in command of the LM. Okay. Vance, I'm probably the only CMP that's ever witnessed a DPS burn sitting on the ascent engine head.
- Fred Haise (LMP)
-
Did you get some? Is there any coming out still? They didn't answer. I think we made it. How's this working out?
- Fred Haise (LMP)
-
It's decreasing now. It'll—it'll—It's cold. I noticed that in the command module. It'll wobble.
- Jack Lousma (CAPCOM)
-
That's affirmative, if you'll take out your contingency book and turn to page Power 6. Over.
- Jack Lousma (CAPCOM)
-
And while you're doing that, let's put ATTITUDE CONTROL, three, switches to MODE CONTROL.
- Jack Lousma (CAPCOM)
-
Okay. And when you get to Power 6, you ought to see a circuit breaker page, panel 11.
- Jim Lovell (CDR)
-
Okay, now, Jack … We have put the TCAs in for the previous procedure. Do you want those out, now?
- Jim Lovell (CDR)
-
Okay. I'm changing those to … back again. First three rows. And you're pulling the ATCA PGNS, huh?
- Jack Lousma (CAPCOM)
-
Okay. Now when we get in the fourth row, we're going to open the IMU OPERATE circuit breaker; and what that means is that we're going to lose the capability to watch your CDUs, so we're not going to be able to see your attitude. Therefore, we will not be able to advise you on which antenna to select for communications. The way we want you to handle that is to turn the LM UPLINK SQUELCH off, and when you hear the noise, switch antennas. We'll be able to see you switch antennas, and it's going to take us about 3 to 5 minutes to establish a lockon again after you switch. After each time that you switch antennas, we will initiate a voice check. And basically when you see the Earth out the window, you can be on FORWARD antenna, and when the Moon's up in the window use the AFT antenna. You copy?
- Jim Lovell (CDR)
-
Okay. We're going to pull the IMU OPERATE circuit breaker, so you won't be able to see our attitude. Therefore, you won't tell us how to switch antennas and we'll enable the—I will turn the—up the SQUELCH OFF so that when we start getting any static, we'll switch antennas and as a thumb rule we could use—with the Earth forward, we use the FORWARD antenna and when we see the Moon we use the AFT antenna.
- Jack Lousma (CAPCOM)
-
That's affirmative, Jim. In other words, we're leaving the antenna switching up to you, and after you switch antennas it's going to take 3 to 5 minutes for us to establish a lockon again, and we'll initiate a voice check. And I'm ready to go on panel 11, row 4.
- Jack Lousma (CAPCOM)
-
Okay. On row 14, under HEATERS RCS SYSTEM A/B-1: open QUAD 1 through 4; under ECS, the only change is—under GLYCOL PUMP close AUTO TRANSFER; under COMM, the only change is: open VHF A RECEIVER, open COMMANDER AUDIO; under PGNS, the only change is: close and leave closed IMU STANDBY circuit breaker, so we can have heaters. Read back.
- Jim Lovell (CDR)
-
Okay. On row 4, we're going to open all four of the heaters—the RCS SYSTEM A and B—the first four circuit breakers. We're going to close the AUTO TRANSFER. We're going to open the VHF A RECEIVER and the COMMANDER AUDIO. And we're going to close the IMU STANDBY. The LGC DSKY and the IMU OPERATE will be open.
- Jack Lousma (CAPCOM)
-
That's affirmative, Jim. All other breakers in that row are as you see them in the checklist. And on row 5, the only change is that we want you to, under EPS, open ASCENT ECA CONTROL. Over.
- Jim Lovell (CDR)
-
Roger. I think we already have that opened—ASCENT ECA CONTROL is probably already open.
- Jim Lovell (CDR)
-
Okay. So let me confirm. We'll have one COMM system, that will be the LMP system, and we'll have to do our own antenna switching; therefore, we'll have to wait about—Okay, why don't you switch? Aft antenna.
- Jack Lousma (CAPCOM)
-
Okay. Panel 16, that's on page Power-7. Top row, the only change is: under RCS SYSTEM B, open PQGS/DISPLAYS. Over.
- Jim Lovell (CDR)
-
Okay. I may go over this with you, Jack, because this checklist has been written over two or three times now on our various procedures. Top row, the first two are open, the next three are closed, and we're going to open now the QUAD TCA's 1, 2, 3, 4; CROSSFEED will be closed, and the TEMP/PRESS DISPLAYFLAG will be opened, and we're going to open up the PQCS, MAIN SOV will be closed, and the … will be opened.
Expand selection up Contract selection down Close - Jim Lovell (CDR)
-
Okay. Again let me go through this with you. The first four are going to be closed. The next sev—eight will be—the next nine will be open from LOGIC POWER B through DESCENT ENGINE OVERRIDE How about the CWEA? Is that going to be closed?
- Jack Lousma (CAPCOM)
-
Okay. In the third row, under COMM: DISPLAY, open; SE AUDIO, closed; VHF A TRANSMITTER, open—That's a change—VHF B RECEIVER, open; PRIMARY S-BAND, POWER AMPLIFIER, open; TRANSMITTER/RECEIVER, closed; S-BAND ANTENNA, open; PMP, closed; TV, open. Under ECS: DISPLAYS, open; GLYCOL PUMP SECONDARY, open; LOC PUMP, open; CABIN FAN CONTROL, open; CABIN REPRESS, closed; and all the next four closed also. Read back.
Expand selection down Contract selection up - Jim Lovell (CDR)
-
Okay. We have DISPLAY, open; SE AUDIO, closed; VHF A TRANSMITTER, open; VHF B RECEIVER, open; POWER AMP's going to be open; TRANSMITTER/ RECEIVER, closed; S-BAND ANTENNA, open; PMP, closed; TV, open; DISPLAY is open; next three are open; CABIN REPRESS, closed; and all the rest closed.
- Jack Lousma (CAPCOM)
-
That's affirmative, Jim. And in row 4, under HEATERS, we want them all—Correction—we want all the QUAD HEATERS open. Correction—we want all the QUAD HEATERS closed.
- Jack Lousma (CAPCOM)
-
We want DISPLAY, open; S-BAND ANTENNA, closed—to avoid a MASTER ALARM, CAMERA—SEQUENCE CAMERA, open; And under EPS, we want DISPLAYs, open; DC BUS VOLT, closed; INVERTER 2, open; ASCENT ECA, closed; ASCENT ECA CONTROL, open; DESCENT ECA, closed; DESCENT ECA CONTROL, closed; TRANSLUNAR BUS TIE, close; we want the CROSS TIE BUS, open; the BAL LOADS, closed; BAT FEED TIEs, closed. How do you read?
- Jim Lovell (CDR)
-
Okay. The four RCS HEATERS will be closed; DISPLAYS, open; S-BAND ANTENNA, closed; CAMERA SEQUENCE will be open; DISPLAY will be open; DC BUS VOLT will be closed; INVERTER 2 open; ASCENT ECA will he closed, but the ASCENT ECA CONTROL, open; DESCENT ECA, closed; DESCENT ECA CONTROL, closed; TRANSLUNAR BUS TIE, closed; and CROSS TIE BUS, open; and BALANCE LOADS, closed; and the BAT FEED TIEs, closed. I have one question, Jack. On panel—on the second line there under LIGHTING, why are we keeping: the FLOODS and TRACK closed? Or are they going to be open?
- Jack Lousma (CAPCOM)
-
Negative. We have the, LIGHTING breakers all closed. Control the lighting with the switches and rheostats. Over.
- Jim Lovell (CDR)
-
Okay. We don't need the floodlights, I don't think, but we can do it that way, I guess.
- Jack Lousma (CAPCOM)
-
And under row 4, under RCS SYSTEMS A/B-2, QUAD HEATERS, you notice that we've closed those circuit breakers, but what we want you to do is to—on panel 3, turn the RCS A/B-2 QUAD switches 1, 2, 3, and 4, off. Over.
- Jack Lousma (CAPCOM)
-
And we're going to watch your quad temps for you, and when we need to warm them up a little bit, we'll tell you to throw those four switches on—on panel 3.
- Jim Lovell (CDR)
-
Okay. Now are we sure that this PTC mode is good enough so we don't … get crossed up later and get out of configuration.
- Jack Lousma (CAPCOM)
-
Stand by 1 on that, Jim. Okay, Jim, as far as we can tell right now, the PTC looks as good as any PTC we've ever seen in a CSM, so we're going to go with what we've got.
- Jack Lousma (CAPCOM)
-
Okay, and if you turn over the page on Power 8, we have the spacecraft functions remaining to you. We've got low bit rate TM. However, we don't have any VHF. We have CWEA. We have GLYCOL PUMPS. We have SUIT FANS. We have CABIN REPRESS for you, and stand by in ATTITUDE CONTROL here. Okay, in ATTITUDE CONTROL, we'll have hardovers for uses in emergency, and for normal usage we want to have a 15-minute delay to get the heaters on to warm them up be before use. How do you read?
- Jim Lovell (CDR)
-
Okay. For emergency, we have the hardovers and for normal use it requires a 15-minute request to get the heaters on.
- Jack Lousma (CAPCOM)
-
Okay, Jim, that concludes our powerdown procedure, and we're waiting for you to get with it.
- Jim Lovell (CDR)
-
Okay, Jack, we'll start. I sure hate to lose the PGNS. I sure hope that procedure for the midcourse is a good one.
- Jim Lovell (CDR)
-
I'll give you this when I'm finished. After we go through this, then you can go through it again and doublecheck it.
- Jack Swigert (CMP)
-
Now, the flood lights are on, right? No, I kind of don't think we need them though, do you?
- Jim Lovell (CDR)
-
Don't pull those. Give me the—first of all. We'll get back there. Those four are close, open, open, ENGINE ARM, open, …
- Jim Lovell (CDR)
-
You're familiar with our particular spacecraft that on panel 16 HEATERS RCS SYSTEMS A and B, QUAD 1 HEATER circuit breaker has been pushed in, and sealed in, and if it's ever pushed out, it's doubtful if we'll ever be able to reset it.
- Jack Lousma (CAPCOM)
-
Okay, Jim, on the four QUAD HEATER breakers, we want you to leave them closed. And we'll operate the heaters with the switches on panel 3. Over.
- Jim Lovell (CDR)
-
(Laughter) I still have one question, Jack. I still think that—I still say that the—on the LIGHTING in our panel 16, the FLOOD lights and the TRACK should be open. We're not using them.
- Jim Lovell (CDR)
-
Okay, Jack, my only other concern now is the CO2 rise in the spacecraft. I guess you're keeping a handle on that?
Spoken on April 15, 1970, 5:21 a.m. UTC (54 years, 7 months ago). Link to this transcript range is: Tweet