Jim Lovell (CDR)

We got pretty good … I'll do an AUTO P52 to Antares. That's the way I'll get it up there.

Charlie Duke

Hey, Houston—correction—Aquarius, Houston. We're satisfied with our present alinement. We don't want you to waste any more RCS gas trying to do this P52, and be advised you guys are hot mike, if you haven't heard. Over.

Fred Haise (LMP)

How's your memory there, Charlie?

Charlie Duke

Okay, we're putting Vance back on. Stand by.

Jim Lovell (CDR)

Okay, okay, let's go back to that P52 … now the attitude.

Jim Lovell (CDR)

Yes. I want to make sure I got it.

Fred Haise (LMP)

Okay. … Okay. You want these numbers? Or do you want the numbers from these.

Jim Lovell (CDR)

I got 13 20 going now.

Jim Lovell (CDR)

… Just a … These are those 13 20 angles here. Up here. Right here.

Jim Lovell (CDR)

Hey, great.

Expand selection down Contract selection up

Spoken on April 14, 1970, 10:38 p.m. UTC (54 years, 8 months ago). Link to this transcript range is: Tweet

Fred Haise (LMP)

One on. And Houston, Aquarius.

Fred Haise (LMP)

Oh, about how long we got before we're going to have to go to work here, Vance. Kind of like to get a bite to eat, maybe.

Vance Brand (CAPCOM)

Okay. We have a—a couple of pads to give you and stand by. Let's—we'll check to see if we have anything else.

Fred Haise (LMP)

Hold on to that, baby. Where's that G&N book? You got it over there?

Jim Lovell (CDR)

Here we go. Here, you want me to start copying —

Fred Haise (LMP)

No, you've got it right here.

Vance Brand (CAPCOM)

Okay. About all we have to do is to send up your state vectors and target loads, and that will have to wait a couple of minutes until we get ready to do so. And if you're ready to copy, I can give you the P30 maneuver pad for PC plus 2, and after that, probably you should eat and then we'll regroup again to send up other things. Over.

Fred Haise (LMP)

Okay. I'm ready to copy a P30, a PC plus 2.

Vance Brand (CAPCOM)

Okay. Okay, this is a preliminary P30 LM maneuver PC plus 2. Starting NOUN 33: 079:27:40.07; plus 0819.2, minus 0020.0, minus 0218.9; NA; plus 0020.9, 0848.2; 420, 274, 082; plus 0820.3, minus 0020.0, minus 0215.0. Comments. Ullage is two jets for 10 seconds. CSM weight, 62480. LM weight 33576. And the following is the DPS throttle profile: 5 seconds at minimum followed by 21 seconds at 40 percent, and the remainder at MAX. Over.

Fred Haise (LMP)

Okay. PC plus 2. 079:27:40.07; plus 0819.2, minus 0020.0, minus 0218.9; NA; plus 0020.9, 0848.2; 420, 274, 082; plus 0820.3, minus 0020.0, minus 0215.0; the rest N/A. Under remarks: ullage, two jets 10 seconds; CSM weight 62480; LM weight 33576. DPS throttle profile: 5 seconds at idle; 21 seconds at 40 percent; remainder at MAX.

Vance Brand (CAPCOM)

Roger; that's correct, Fred. If you'll take out a maneuver pad, I'll give you some landing information. Over.

Fred Haise (LMP)

Okay, you're talking in the CSM update book?

Fred Haise (LMP)

You got it right here. Make sure and scratch the … —

Fred Haise (LMP)

Okay, which—which one we want? P37?

Jim Lovell (CDR)

What kind of a maneuver pad do you want, Vance?

Vance Brand (CAPCOM)

This is a CSM maneuver pad for—to monitor PC plus 2. And it's going to be mainly blank except I want to give you your NOUN 61 latitude and longitude range to go for the EMS and that sort of thing.

Vance Brand (CAPCOM)

Okay, at the top, purpose is monitor PC plus 2; everything is blank until you get down to NOUN 61. Latitude as follows: minus 21.47, minus 165.00; 1166.0, 36291, 142:39:20. Over.

Fred Haise (LMP)

Okay, monitor PC plus 2 pad. NOUN 81: minus 21.47, minus 165.00; 1166.0, 36291, 142:39:20.

Vance Brand (CAPCOM)

Roger; that's correct, Fred-o. And we—now would like to get you in a configuration to uplink your state vector and target load. So, if you're ready to copy, I have some circuit breaker changes for you. Over.

Vance Brand (CAPCOM)

Okay, circuit breaker panel 11 UPDATA LINK, CLOSE; PRIMARY POWER AMPL, panel 16, CLOSE; VOICE FUNCTION to VOICE; RANGE—RANGING FUNCTION to RANGING; TM bit rate, HI; and then P00 and DATA.

Fred Haise (LMP)

Okay, we're now in P00 and DATA, and switches and breakers are configured. You got it.

Vance Brand (CAPCOM)

Okay, thank you. You're coming in loud and clear.