- Joe Kerwin (CAPCOM)
-
Roger, we understand that. It is strictly a downlink problem and you can stay in the DOWN VOICE BACKUP mode if you want. If we get involved in conversation, I think we'll want to go back to NORMAL voice.
- Joe Kerwin (CAPCOM)
-
Fred, Houston. Understand you'd like to know the GET of your initial powerup, is that correct?
- Joe Kerwin (CAPCOM)
-
Okay, we don't have a percise time for the starting of that procedure yet; we are working on it real hard. It won't be for several hours; and we'll pass it up to you just as soon as we get it. Over.
- Joe Kerwin (CAPCOM)
-
Okay. Our estimate is that we will start powering up for the DPS burn at about 76 hours elapsed, which is about 6-3/4 hours from now.
- Fred Haise (LMP)
-
Okay, Joe, about 76 hours or so and I guess you misunderstood. My question was what was the GET way back when, when I first came across to the LM and transferred to LM power? How long have we been living on the LM, now?
- Joe Kerwin (CAPCOM)
-
Okay, the time of transfer to LM power was 57 hours, 11 minutes. For your information, we seem to be reasonably fat on power. In fact, we are looking at a procedure that we might recommend to you later on after the burn and so forth of powering up one of the command module main buses via the LM umbilical. This would enable us possibly to charge up the command module batteries. Over.
- Fred Haise (LMP)
-
Okay, Joe. That sounds great. I just thought that to pass the time, I'd do a little backseat quarterbacking, here.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. I have a few words for you on some things we want to do in the next few hours, and in order to get good COMM for that and also in order to give FIDO a few minutes of ranging, I want to have you put the POWER AMPLIFIER circuit breaker in panel 16 in, the VOICE FUNCTION switch to VOICE, and RANGING FUNCTION switch to RANGING. Over.
- Joe Kerwin (CAPCOM)
-
Okay, Fred. And you're loud and clear down here now. Okay. What we're getting a procedure ready for you is to do an AOT Sun check at approximately 74 hours or in just a little over 3 hours. That will be a detent 2; we'll have a detail procedure up shortly and it will include a rendezvous radar redesignation to get it out of the way and a P52 maneuver to the attitude. It's our feeling that if that checks out within 1 degree that your platform will be okay for the burn without a subsequent P52. If it's not within 1 degree, we are working up an Earth/Sun alinement procedure to aline the platform, and we'll have that up to you later. Okay. Assuming that the Sun check is okay, we will then give you a star for a confidence check on the back side when you're in the darkness. We'll be updating a burn pad to you prior to LOS going around the Moon. We'll have another look at you after AOS, and we'll update the pad if required. Right now that update should be very small. Over.
- Fred Haise (LMP)
-
Okay. Stand by 1.
Expand selection down Contract selection up
Spoken on April 14, 1970, 5:02 p.m. UTC (54 years, 6 months ago). Link to this transcript range is: Tweet